Enter Analysis Results
Explanation
Use this activity to enter analysis results for an analysis.
This activity contains a Security Checkpoint which can be activated by an
administrator. With an activated security checkpoint on a function you will have
to authenticate yourself again in order to fulfill the function. Additionally,
whenever a security checkpoint is successfully passed a security checkpoint log
is written, creating an audit trail of what is done.
Prerequisites
An analysis must have been created for the appropriate receipt,
purchase order, shop order, production schedule, or inventory function.
System Effects
As a result of this activity:
- Results are entered
for the analysis. These results can be used to create various IFS/Quality Management
charts.
- When a double sampling plan is used and the first sample was neither
accepted nor rejected, another sample is needed and a new analysis is
created.
- Switching score for switching to reduced inspection and qualification
score for skip lot will be calculated after confirming results.
Window
Analysis Results
Related Window Descriptions
Analysis Results,
Analysis
Procedure
- Either populate or query to display the appropriate analysis in the
Analysis Results window.
- Select the
line for which you want to report results.
- If the data type is Attribute, enter your results in the Noncomformities (c/u) and/or
the Noncomforming (np,p) columns in the
Attribute tab. If the
data type is Variable, enter your results in the Result column in the
Variable tab by entering as
many measurement values as the specified sample size.
- Save the results.
- Choose Complete Registered Results
from the right mouse button (right mouse button) menu. This changes the status for the
selected line to Complete. Only results with this status are considered when creating control charts or calculating capability indices.
Once the line has this status, the results cannot be edited.
- If SPC is
activated in the Control Plan, you can create a new control chart by
selecting a line and choosing Create SPC Chart from the right mouse
button menu.
- You can
print a test instruction by choosing Print Test Instruction from the right mouse button
menu in the header of the window. This test instruction includes all Control Plan lines.
- You can add document text to any line by choosing Document Text from the
right mouse button menu.
- You can print a report of your results for any line
by choosing Print Data Sheet from the right mouse button menu.
- When all
test operations have been reported, you can change the status for the analysis to Confirmed by selecting Confirm Registered Results from the
right mouse button menu from the header of the analysis. Once an analysis has Confirmed
status, the results cannot be edited.
- Alternatively, you can confirm multiple analyses
at a time in the Analysis window by selecting one
or more analyses and choosing Confirm Registered Results from the right mouse button
menu.