Report Counting
Explanation
This activity is used to enter the results of your physical counting
of inventory parts without using a count report.
Prerequisites
- The inventory parts must have been received at the desired inventory location.
- If counting limits are to be used, they must have been entered on the Site/Extended
Site Info/Inventory
tab.
- The part should not have the planning method O, K, T.
System Effects
- Any divergence between the quantity stated in the system and the quantity physically
counted will be shown in the created inventory postings, in the Acc Count Difference field in
the
Count
Per Inventory Part window
and in the Acc Count Diff field on the Inventory
Part/Misc Part Info tab.
- If a limit is used for the site where the parts are counted, the counting results that
do not meet the limits will be rejected. In such a case, the result must be approved manually
and a re-counting can be performed. Rejected counting results do not change the quantity on-hand until it has been approved.
Note: The part will always be frozen until the count result is
approved or canceled.
- If you had entered a note in the Note field in the Count
Per Inventory Part window, this will be carried forward and displayed in
the Query - Count Results and Count Result Per Inventory
Part windows.
If the inventory transactions are created, the note will be included in them.
Note: You cannot carry out counting in the project inventory for a closed project activity, as it is not possible to increase the counting quantity for such a location. Instead, a positive counting difference should be added to a standard inventory location, or to another project inventory location where the activity has not already been closed.
Window
Count Per Inventory Part
Related Window Descriptions
Count Per Inventory Part
Count Per Inventory Part/General
Count Per Inventory Part/Pallet
Define Cost Structure
Procedure
- In the Count Per Inventory Part window,
populate or query for the desired part number. The lower part of the window shows all
the locations at which the part is registered. You can also see the quantity at each location.
- Enter the quantity counted at each location in the Quantity Counted field.
- If required, you can enter a note in the Note
field regarding the counting results you have entered. (This note will be
carried forward and displayed in the subsequent windows for counting, and can
aid you in decision making).
- If the part is catch-unit-enabled, enter the catch
quantity in the Catch Qty Counted field.
- If the part is a serial part, enter a serial
number in the Serial No field.
- Save the information.
If the counted part has not been received into stock
prior to counting, you will have to define the cost structure for the part
manually. If this is the case, the Define Cost Structure dialog
box will open upon saving.
The cost structure could be defined either by manually entering all the details, or
by using the Split Cost button:
To manually enter the cost details:
- To add a new line, click New. Click on
the Cost Bucket ID field and select a suitable cost bucket from the
List of Values.
- If you are using cost details, enter suitable
values in the Cost Source ID and the OH Accounting Year fields.
- Enter a value in the Cost/Unit field.
- Repeat steps 1—3 and enter as many new cost detail
lines as required. Note that you should always maintain at least one line
with a material
type cost bucket in your cost structure.
- Click OK.
When using the Split Cost feature:
- Click Split Cost.
- In the Split Costs into Details
dialog box that opens, enter a value in the Total Unit Cost field.
- Click OK. The total cost will be split into
cost detail lines in accordance with the settings in IFS/Costing.
Finally, if the counting result did not meet the
specified limits, a message is displayed that it has been rejected and that approval is
necessary.