Enter Analysis Results for Inventory Part
Explanation
Use this activity to enter analysis results for an inventory part.
This activity allows you to record the measure quality results against the
quality test plan (Control Plan) for an inventory part where required.
You can change the status of a data point to Complete. Only data points in
Complete status are considered when creating control charts or calculating capability indices.
Once the data point has this status, the results cannot be edited. You can also create a new control chart
if SPC is
activated in the control plan.
When all
data points for an analysis have been reported, you can change the status to
Confirmed.
Once an analysis has been confirmed, the results cannot be edited.
This activity contains a Security Checkpoint which can be activated by an
administrator. With an activated security checkpoint on a function you will have
to authenticate yourself again in order to fulfill the function. Additionally,
whenever a security checkpoint is successfully passed a security checkpoint log
is written, creating an audit trail of what is done.
Prerequisites
This activity has the following prerequisites:
- A Control Plan header and one or more control plan lines must exist. The
Control Plan must be in the Active status.
- To be able to enter analysis results, an analysis
must exist in the Planned status.
System Effects
As a result of this activity, results are entered for an inventory part.
Window
Analysis
Results
Related Window Descriptions
Analysis
Results
Analysis
Procedure
- If you just created the analyses, you are prompted to indicate
whether you want to view the created analysis overview. If you click Yes, the
Analysis
Results - Inventory window opens.
- If you are working on previously created analyses, open the Analysis
Results window and query for the part for which you want to enter
data.
- If the part is serial tracked and variable data type results need to be
entered, right-click on the header and click Enter Serial Numbers.
The Enter Serial Numbers dialog box is opened. Select the
Selected Serial No check boxes for the corresponding serial numbers of
the parts included in the analysis. Click OK.
- If the part is lot/batch tracked, and if the corresponding lot/batch
number has not been filled in Lot/Batch No field in the header, then
enter a value in the Lot/Batch No field. Use the List of Values to
select a suitable value.
- Optionally, in the Analysis Results header, select a
filter value for the Data Point Filter field to populate the analysis
according to the selected option.
- For data points defined as variables, select the Variables tab
and enter your results in the Result field. For serial tracked parts,
the serial number also needs to be entered in the Serial No field.
Use the List of Values to select a suitable value.
- For data points defined as attributes, select the Attributes tab
and enter your results in the Nonconformities (c/u) and/or the
Nonconforming (np,p) fields.
- Save the changes.
- To change the status to Complete, right-click and then click Complete
Registered Results.
- To create a new control chart if SPC is activated in the control plan,
right-click on the line and click Create SPC Chart.
- To print a test instruction, right-click in the header and then click
Print Test Instruction. The test instruction includes all control plan
lines.
- To add document text to any line, right-click and click Document Text.
- To print a report of your results for any line, right-click and click
Print Data Sheet.
- To confirm a single analysis, right-click in the header of the analysis
and then click Confirm Registered Results.
- To confirm multiple analyses, select one or more analysis in the
Analysis window, and then right-click and click Confirm Registered
Results.
- When the analysis results are confirmed, the values
in the Variable Result Status and Attribute Result Status
fields are calculated automatically.