Receive and Backflush Components

Explanation

Use this activity to receive manufactured parts into inventory and to automatically issue the material. 

However, if catch unit enabled components are issued using the backflush feature, this activity can be performed only if the full quantity on the inventory location is issued.

When automatically issuing material, below parameters are considered.

This activity contains a Security Checkpoint which can be activated by an administrator. With an activated security checkpoint on a function you will have to authenticate yourself again in order to fulfill the function. Additionally, whenever a security checkpoint is successfully passed a security checkpoint log is written, creating an audit trail of what is done.

Prerequisites

This activity requires that:

System Effects

As a result of this activity the system receives parts into inventory and automatically issues material based on the number of parts received. The material is primarily issued from work center inventory or, as a second choice, from the regular inventory locations according to the FIFO (First In, First Out) principle.

The supply code of the shop order material lines is considered during the automatic issue of parts. If the supply code is Inventory Order, only the standard inventory will be available for issue. 

If the supply code is Project Inventory, only the project inventory of the project connected to the shop order will be available for issue. If components are available, the parts belonging to the connected project activity will be issued.

If the shop order is connected to a project activity, the parts will be received into project inventory.

If the shop order is created from Project Delivery, the delivery project will be updated with the quantity received.

If the shop order is created from Project Miscellaneous Demand, the project miscellaneous demand record will be updated with the quantity received.

If the shop order is pegged to a project miscellaneous demand or a project item, the material will be automatically reserved to the demand source. 

If the shop order is marked as customer order-based and was created when a customer order line was entered, the received part is automatically reserved for the customer order line. Work In Process (WIP) transactions are created.

When issuing material by using backflush for a pegged shop order, the issue will reduce the pegged quantity by the same quantity that was issued. However, if there is more than one supply pegged to the same demand you will be notified to manually adjust the peggings before the issue can be performed.

Window

Shop Order
Shop Orders
Receive Shop Order
Shop Floor Workbench

Related Window Descriptions

Shop Order
Shop Orders
Receive Shop Order
Shop Floor Workbench/Approve Operation

Procedure

Shop Order or Shop Orders:

  1. Right-click and then click Manual Receive. This opens Receive Shop Order window.
  2. Select the Receive with Backflush check box in the Material And Operations area to automatically issue material.
  3. Select an inventory location for the part, then enter the quantity you want to receive into this inventory location in the Quantity Received field. You can receive into more than one inventory location.
  4. If you do not want to receive into one of the specified inventory locations, create a new record and type a new inventory location in the Location No field. Type the quantity of parts you want to receive in the Quantity Received field. Use the List of Values to select from available locations.
  5. You can also define the following fields W/D/R No, Expiration Date, Availability Control ID, Condition Code and Catch Quantity depending on your preference.
  6. Save.

Receive Shop Order:

  1. Select the shop order for which you want to receive the completed parts in the Order No list.
  2. Select the Receive with Backflush check box in the Material And Operations area to automatically issue material.
  3. Select an inventory location for the part, then enter the quantity you want to receive into this inventory location in the Quantity Received field. You can receive into more than one inventory location.
  4. If you do not want to receive into one of the specified inventory locations, create a new record and type a new inventory location in the Location No field. Type the quantity of parts you want to receive in the Quantity Received field. Use the List of Values to select from available locations.
  5. You can also define the following fields W/D/R No, Expiration Date, Availability Control ID, Condition Code and Catch Quantity depending on your preference.
  6. Save.

Approve Operation

  1. In the Shop Floor Workbench , select the last operation on the shop order on which you want to receive the completed parts, and click Approve Operation.
  2. In the Approve Operation dialog box, make sure the Receive Into Inventory check box is selected.
  3. Click the Receive with Backflush check box.
  4. Enter the quantity to receive in the Qty to Receive field.
  5. Choose an inventory location the parts should be received to by entering a value in the Receive Into Location field or use the List of Values.
  6. You can also define the W/D/R No, Expiration Date, Availability Control ID, Condition Code and Catch Quantity fields using Receive Parameters dialog box which can be opened by Receive Parameters button.
  7. Click OK.