Change Part Revision

Explanation

This activity is used to change the part revision of a serial. The part revision of a serial can change as a result of embodying a modification on the serial or due to configuration changes on the serial.

If you need to change the part revision of a serial that is installed in a structure, the new part revision must have been defined as a valid alternate for the given structure position or for the part in the template. If the serial is not installed in a structure, the different configurations (templates) for the part will be used to determine the new part revision. A change of part revision can lead to a change of template for the serial. In such cases, one or all of the following will occur as part of this activity:

Prerequisites   

System Effects

Window

Serial Structure Information
Serial Structures

Related Window Descriptions

Change Part Revision - Step 1
Change Part Revision - Step 2
Change Part Revision - Step 3
Change Part Revision - Step 4
Serial Structure Information
Serial Structure Information/Consist Of
Serial Structures

Procedure

  1. Open the Serial Structure Information window and query (F3) for your serial structure.
  2. If you need to move down the structure, click the Consist Of tab, select the row that contains the part, right-click, and then click Next Level until the required serial part is displayed in the header of the window.
  3. Right-click anywhere in the header and then click Change Part Revision. The Change Part Revision assistant will open.
  4. In the New Revision field, enter the new part revision. Click List to select a valid value.
  5. Optionally, you can define a manufacturer part number for the new revision in the New Manu. Part No field. Click List to select a valid value.
  6. If you want to assign a maintenance program to the new part revision, enter a value in the Maint Program ID field. Click List to select a valid value.
  7. If a maintenance group is required for the new part revision, enter a value in the Maint Group field. Click List to select a value.
  8. If you want to disconnect the serial from the current maintenance program, select the Disconnect Serial from Maint Program check box. Note: This check box will only be available when valid maintenance programs do not exist for the new part revision.
  9. Click Next.
  10. The second step of the assistant opens if the new part revision is to be created for a serial that is not installed in a structure. Here you can change the template structure for your new part revision.
  11. In the Template Part No field, click List to select the template part for the serial structure template you want. Similarly, select the appropriate revision and structure position for this template part in the Templ Rev and Structure Position fields.
  12. Click Next.
  13. In the third step of the assistant, you can update the child parts which are defined in the structure of your new part revision.
  14. In the Structure Position field, set the correct structure position for the selected template structure. Click List to select the value.
  15. Click Next.
  16. In the fourth step of the assistant, you can select the access groups that will have access to the new part revision of the serial.
  17. The Implement For check box is selected by default. You need to clear this check box for the access groups that will not have access to the new part revision.
  18. Click Finish.

Note: This procedure may be performed using the Serial Structures window as well.