Prepare to decomply a performed modification
Explanation
This activity is used to create a pending maintenance event for the decompliance of a
modification.
When a modification is complied with, all defined actions are performed as
specified. However, occasions can arise where previously performed actions need
to be reversed (in other words, you need to decomply a modification). This can be
performed using the Create Maintenance Event for Decompliance option. With this option, a new
modification event containing the modification execution type decomply, is used
to reverse the action of the modification that was previously performed.
When a modification of execution type Terminating
Action leading to a part identity change is complied with, the serials assigned
to and/or affected by the modification is automatically renamed to the new part
number and revision. The Create Maintenance Event for Decompliance option can be used to
create a pending event for the modification to reverse the performed serial
rename. Once the decomplied modification event is finished, the renamed serial
will be reversed back to its origin defined on the modification.
This means that the renamed serial will be changed automatically and will
include the old part number used before the serial was renamed. If history
records were updated with the new part number of the renamed serial, these
records will be updated once more to include the old part number of the serial.
Prerequisites
- A historical modification (i.e., the modification is
completed) with either an Active or an Obsolete status, must exist for the
serial. Both pending and running decomply events can be defined for
obsolete modifications.
- The Decompliance Allowed check box must be selected for the part
assigned to the modification. For more information on connecting parts to a
modification, refer the online help file
Assign Parts to Modification.
- If the modification has been complied with, the
compliance status for the modification must be Complied. (Initial or
continued inspections cannot be decomplied at this stage.)
- The modification that will be decomplied must have the execution type
Terminating Action. Furthermore, the Decompliance Allowed check box
must be selected for the modification.
- If a part identity change performed on a serial
through the embodiment of a modification is to be reversed, a pending event
for the decompliance of the modification must exist.
System Effects
- A pending event for the decompliance of the modification is created, and the
event is available for normal maintenance event distribution.
- When a referenced modification with a reference type of
Mandatory is decomplied for a serial, the pending event created for the
referencing modification is removed.
- When a decomplied modification event leading to a
part identity change is finished, the serial is reversed back to its origin
defined on the modification.
- When a decomplied modification event leading
to a part identity change is finished, and history for the serial has been
updated with the new part number, these history records will be updated once
more with the old part number and revision.
Modifications that can be decomplied
Define
Modification
Serial Modification History
List
Serial Modification History
History per Serial
Maintenance Event Summary
Reconfigure Work Scope
Related Window Descriptions
Modifications that can
be decomplied
Define Modification/History
Serial Modification History List
Serial Modification History
History per Serial/Modification
Pending Maintenance Events
Component Life/Modification Compliance
Maintenance Event Summary/Modification
Reconfigure Work Scope/Modification
Procedure
General - If post maintenance checks (PMCs)
exist after the modification has been complied with, you can choose to remove
these PMCs immediately, or after the decomply event for this modification is
completed.
Select from the following options to create a pending
event for the decompliance of a modification. A decomply event can be created from
any of the windows listed under Window.
Procedure 01:
- Open the Modifications that can be decomplied
window. You can also perform this procedure from one of the windows listed
under Window.
- Query (F3) for the serial and modification event
you want to decomply.
- Select the relevant row, right-click and then
click Create Maintenance Event for Decompliance.
- A message appears requesting confirmation of the
event. Click OK to create a new pending event.
Procedure 02:
(Ideally, this procedure would be performed for
modifications that relate to a complex MRO flow.)
- Open the Maintenance Event Summary window. Note
that this procedure can also be performed using the
Reconfigure
Work Scope window.
- In the Work Order field, query (F3) for the
work order to which the serial and modification you choose to decomply
belongs.
- Click the
Modification tab.
- Select the All PCW option. For example, if
the required modification is included in a baseline, select this option from
the Baseline Modifications area. As a result, the table in the
window is populated with the modifications that are currently complied with.
- Select the row containing the required event,
right-click, and then click Create Maintenance Event for Decompliance.
- A message appears requesting confirmation of the
event. Click OK to create a new pending event.