Non Routine
A non routine is a fault that is discovered during the
repair phase of a scheduled maintenance which needs to be corrected in the
ongoing work scope. In order to repair a non routine fault, it must be reported
on the work order or work task on which it was discovered.
The non routine can be reported with one of the
following fault execution types:
- Pending fault - The fault will be repaired
as part of the current work scope.
- Partially Repaired – This is used to indicate that some work has
already been performed. The time spent by a resource or material utilized
for the work can be reported. In
addition, it is possible to enter condition measurement values if condition measurement
requirements have been defined for the task card. The fault is automatically
included in the work scope and the task cards and subtasks are set to finished
if all criteria are met.
- Already repaired - This is used to indicate
that the non routine fault has already been repaired.
Fault Event
A maintenance event is created automatically in Fleet and Asset Management when a non routine is reported with either the Pending
fault or Partially repaired fault execution. The fault event is
added to the maintenance order for the ongoing work scope. If the maintenance
order is distributed with the distribution type,
- Execution Logic Structure - The task cards connected to this
event will be transferred
automatically to the relevant work orders based on the ELOs (execution logic
orders) in the execution logic structure defined on the maintenance order. If
a relevant work order does not exist, i.e., the ELO is not defined in the
execution logic structure on the maintenance order or the work order for the
ELO the task cards are mapped into is already finished, a new work order
will be created automatically and added to the work order structure.
- Work Order - A new work order is created
and the task cards that are connected to the event
will be transferred automatically to this work order.
A historical work order is generated when the non
routine is registered with the Already repaired fault execution.