Reset Value After Repair
Explanation
This activity is used to manually reset the Value After Repair to zero
for a serial at the conclusion of a maintenance visit. If required, the value
can be reset for all serials in its structure as well.
Prerequisites
- To reset the value for a serial, the connected maintenance event must be
in the Started, Work Done or Finished status.
- The reset cannot be done for an overhaul/cycle event since completion of
this event already resets the values for value after overhaul and value
after repair.
System Effects
- The Value After Repair will be reset to zero for all operational
parameters for the serial connected to the maintenance event. If selected,
the value will be reset for all serials in its structure as well.
- A new operational logging will be generated when the Value After Repair
is reset.
- A text will be added to the Measure Remark field on the generated
operational logging, indicating that the logging was created because of a
reset and not because of an actual logging.
Window
Maintenance Order
Related Window Descriptions
Maintenance
Order
Maintenance Order/Maint.
Order Str./Event Details
Maintenance Order/Included Events
Procedure
- Open the Maintenance Order window and query (F3) for the
necessary maintenance order.
- Click the Maint. Order Str. tab. and then the
Event Detail sub tab or the
Included Events tab.
- Right-click and then click Reset Value After Repair. The
Reset Value After Repair dialog box opens.
- Enter a date in the Reset Date field. This date will be set as
the last measure date for the operational logging generated when the
Value After Repair is reset. For maintenance events in the Finished
status, the finish date of the maintenance event will be set by default, but
you may adjust this date. The date cannot be earlier that the date of the
last operational logging for the serial.
- If required, select the Reset all serials in the structure check
box to reset the value for all components in the structure of the serial.
- Click OK. As a result, Value After Repair will be reset to
zero for the serial connected to the maintenance event, as well as its
serial structure.